USER MANUAL OLC/OLCT 100 Norrscope

+

OLCT 100 XP HT 15,5 to 32 110 1705 OLCT 100 XP LEL 15,5 to 32 100 1550 OLCT 100 XPIR 15,5 to 32 80 930 OLCT 100 XP EC 11 to 32 23,5 260 OLCT 100 IS EC 11 to 32 23,5 260 OLCT 100 XP SC 15,5 to 32 100 1550 Simtronics

OLCT 60 Lauper Instruments

+

Top brands. other → Top types Electric scooters Motor vehicle accessories components Top brands. Razer other →

Series 60

+

The OLCT 60 Series is composed of several versions: • XP or IS sensor (toxic or oxygen versions) • Remote or onboard OLCT 60AD version allows the sensor to be intsalled remotely up to 15 meters (standard), allowing detection in inaccessible locations, or in Zone 0 in the case of the intrinsically safe (IS) version. The detector units are made of 316L stainless steel, and are ...

GF00226GEN MX32V2 8pBroA4(1)

+

CH4 MOY 8h:22 Capteur OK Fonctionnement normal 100 0 50 30 88 4 AL1 1 2 3 5 Page précéd. Page suivante Voir 8 capteurs Menu Extracteurs %LIE 1 CH4 100 0 Turbine gaz Sud %LIE 7 CH4 100 0 Local variateur %LIE 7 CH4 100 0 Compression %LIE 21 CH4 100 1 MX 32 1 Measure Range, gas and detector tag 2 Detector address 3 Current value with unit and detected gas 4 Averaged value on the …

OLCT60

+

The OLCT 60 Series is available in several versions: • Explosionproof XP or intrinsically safe IS sensor (combustible, toxic or oxygen versions). • Remote or onboard sensor. The OLCT 60 can be remotely mounted, allowing detection in inaccessible locations or in Zone 0 or 20 in the case of the intrinsically safe (IS) version. • Infrared XP IR sensor or OLCT IR transmitter. The OLCT 60 ...

Oldham OLCT 60 Keison Products

+

GAS TRANSMITTER type OLCT 60 approved ATEX II 2 GD (fitted with XP sensor) delivered without cablegland : WC6EXSAA OLCT 60 for combustible gases, 0 LEL WC6APSAA OLCT 60 for comb. gases, antipoison resistant 4F sensor, 0 LEL WC6ECSAA OLCT 60 for comb. gases, catharometric sensor, 0 vol CH4 OLCT60XP0611 OLCT 60 for , catharometric …

Oldham OLCT 60d LEL CH4 / O 6M2 8983 gas sensor | eBay

+

Gas detector Oldham OLCT 60d LEL CH4. If you are not satisfied with the product write to us.

Fixed Transmitters in Airoli , Navi Mumbai , Industrial ...

+

The OLCT 60 Series is composed of several versions: • XP or IS sensor (toxic or oxygen versions) • Remote or onboard sensor. The OLCT 60AD version allows the sensor to be intsalled remotely up to 15 meters (standard), allowing detection in inaccessible locations, or in. View Complete Details . Contact Seller Ask for best deal. Get Latest Price Request a quote. Industrial Scientific India ...

OLCT 60 Industrial Gas Detector | Teledyne

+

The OLCT 60 is a generation of high quality gas detectors which covers all industrial needs for a variety of applications. The OLCT 60 Series is composed of several versions: XP or IS sensor (toxic or oxygen versions) Remote or onboard sensor. The OLCT 60AD version allows the sensor to be installed remotely up to 15 meters (standard), allowing detection in inaccessible locations, or in Zone 0 ...

Description

+

The OLCT 60 Series is available in several versions: • Explosionproof XP or intrinsically safe IS sensor (combustible, toxic or oxygen versions). • Remote or onboard sensor. The OLCT 60 can be remotely mounted, allowing detection in inaccessible locations or in Zone 0 or 20 in the case of the intrinsically safe (IS) version. The OLCT 60 is equipped with a local display and nonintrusive ...

Oldham OLCT60 Industrial Fixed Gas Detector with Display

+

The OLCT60 from the Oldham Gas Detection range is a highquality industrial gas detector designed for the detection of flammable, toxic gases or oxygen.

DETECTORSTRANSMITTERS

+

SERIES 60 The OLCT 60 SERIES is composed of several versions • IS or FLP cell (toxic or oxygen versions) ... CH4 catharometre 0 vol 20°C to +50°C H2 catharometre 0 vol 20°C to +50°C NH3 catalytic 05000 20°C to +50°C Flammable gas catalytic 0 LEL 20°C to +70°C20°C to 200°C * temperature at 20°C and at Atmospheric Pressure Gases SIADF O2 YES YES CO YES YES …

Gas Detection Control Panel

+

CH4 8h:22 avg Detector OK Normal 100 0 50 30 88 4 AL1 1 2 3 5 previous page Next page See 16 detectors Menu Compressor 2 %LEL 1 CH4 100 0 Compressor 1 %LEL 7 CH4 100 0 Turbine 2 %LEL 7 CH4 100 0 Turbine 1 %LEL 21 CH4 0 1 Calibration Curve Simplified procedure that enables time savings ( nonintrusive and oneman calibration). 1 Calibration curve 2 Cursors for span settings 3 …

Introducing the OLCT 60 detectors designed for the ...

+

The OLCT 60 Series is available in several versions: • Explosionproof XP or intrinsically safe IS sensor (combustible, toxic or oxygen versions). • Remote or onboard sensor. The OLCT 60 can be remotely mounted, allowing detection in inaccessible locations or in Zone 0 or 20 in the case of the intrinsically safe (IS) version. • Infrared XP IR sensor or OLCT IR transmitter. The OLCT 60 ...

OLDHAM OLCT 60D LEL CH4 / O 6M2 8983 gas sensor 1,792 ...

+

OLDHAM OLCT 60D LEL CH4 / O 6M2 8983 gas sensor 1, FOR SALE! Welcome to the Patkor store auctionIn this auction we offer: Gas detector 185038702690

MX 16 Teledyne | Teledyne

+

MX 16 + OLCT 10N O₂ MX 16 + OLCT 10N CO₂ ... CH4 Capteur OK Fonctionnement normal 100 0 50 30 88 3 AL1 1 2 4 Controller Normal mode By default, the MX 16 can store up to 512 alarm events, 512 fault events and 512 system events. Simplified procedure that enables time savings ( nonintrusive and oneman calibration). Alarm mode Grayscale mode in alarm conditions for immediate ...

OLDHAM OLCT 60 D Gas Detector Catharometric 0 VOL FLP ...

+

OLDHAM OLCT 60 D Gas Detector Catharometric 0 VOL FLP WC6ECSAA 6513525 New EUR 600,92. ZU VERKAUFEN! Description Oldham OLCT 60 D Gas Detector Catharometric 0 VOL FLP WC6ECSAA 113136694601

OLCT60 gas detector

+

155 mA (OLCT 60 / OLCT IR, the peak value of the current 550 mA) 120 mA (IR XP IR) 80 mA. Output signal: 0 23 mA (detection reserved 420 mA) Cables: 3 Effective conductor shielded cable. Maximum cable loop resistance / controller connected Odum maximum length: Catalytic combustion: 32 Ω / 1 km mm2 (16 AWG) Electrochemical and XP IR: 48 Ω / km mm2 (16 AWG) OLCT 60 / …

OLDHAM OLCT 60D NO / O gas sensor 6M2 9159 1, ...

+

OLDHAM OLCT 60D NO / O gas sensor 6M2 9159 1, FOR SALE! Welcome to the Patkor store auctionIn this auction we offer: Oldham OLCT 185038774129

Replacement Sensors Multimarga is the distributor of ...

+

Catharometric sensor for OLCT 20/40/50/60/80, 0 vol CH4: 6313986: Catharometric sensor for OLCT 20/40/50/60/80, 0 vol H2: 6313369: O2 sensor for MX 11 CTX 50 CTX 100 CTX 200: 6313585: O2 sensor, 030 % for 2042: 6313754: O2 sensor for CTX 300: 6313660: O2 special sensor for CTX 300: 6313710 : O2 030%vol sensor block for FLP OLCT 20/40/50/60/80: 6313748: O2 030%vol …

HATECH GASDETECTIETECHNIEK BRASEM 51 4941 SE ...

+

CH4 ectro years arra US Pending DEVICES ÈêEx INCRIS smFS DE ''NMETRO The Fixed Gas Detection Experts . OÆDHAM APPLICATIONS Steel mills Petrochemical facilities Chemical industry Pharmaceutical industry Food industry Refrigeration industry Water treatment IR SENSOR The infrared sensor provides detection of C02 and is warranty 3 years The OLC/OLCT 100 range of fixed …

OLCT 60 détecteur de gaz fixe avec afficheur | Teledyne

+

OLCT 60, une génération de détecteurs de gaz de haute qualité qui couvre tous les besoins industriels et diverses applications. La série OLCT 60 est composée de plusieurs versions : Capteur ADF ou de SI (versions gaz toxique ou oxygène) Cellule déportée ou locale. L''OLCT 60AD permet la détection des gaz à distance : la cellule est ...

OLDHAM OLCT 60 Gas Detector

+

The OLCT 60 Series is composed of several versions:• XP or IS sensor (toxic or oxygen versions)• Remote or onboard sensor. The OLCT 60AD version allows the sensor to be intsalled remotely up to 15 meters (standard), allowing detection in inaccessible locations, or in Zone 0 in the case of the intrinsically safe (IS) detector units are made of 316L stainless steel, and are ...

OLCT 200 Teledyne

+

OLCT 200 Sensors Technical Specifications Sensor Type Target Gases Measuring Range Resolution Accuracy Response Time (T50 / T90) Temp Range (°C) Humidity Range (%RH) Default Alarms (A1 / A2) Combustible Gases (LEL) Methane (CH4) Calibration 0100 %LEL 1 %LEL +/ 1 %LEL CH4 5 / 10 sec 40 to 60 0 95% 10 / 20 %LEL Combustible Gases (LEL) Pentane (C5H12) Calibration 0 …

Gas DeTecToR olcT iR

+

OLCT IR combined with an OLCT 60 accessories • Magnetic key for maintenance • Weatherproofing • Mounting bracket • Gas intake pipe • Calibration cup • Mosquito guard. Detection principle • Optics: infrared absorption Detected gases • Hydrocarbons • Methane, propane/butane as standard • Others on request including CO 2 Range • 0 LEL CH 4, C 3H 8, C 4H 10 • 0 of

laissez un commentaire